Products
11KV Indoor vacuum Load Break Switch
  • 11KV Indoor vacuum Load Break Switch11KV Indoor vacuum Load Break Switch
  • 11KV Indoor vacuum Load Break Switch11KV Indoor vacuum Load Break Switch
  • 11KV Indoor vacuum Load Break Switch11KV Indoor vacuum Load Break Switch
  • 11KV Indoor vacuum Load Break Switch11KV Indoor vacuum Load Break Switch

11KV Indoor vacuum Load Break Switch

Wzonpa, a professional manufacturer and supplier in China provides the 11KV Indoor vacuum Load Break Switch featuring a compact integrated structure, vacuum arc extinguishing technology, and reliable mechanical interlocking. It delivers stable switching performance, enhanced operational safety, and reduced maintenance, making it suitable for modern medium-voltage distribution systems requiring efficient and secure load control.
Rating: 5.0
(Rating Count: 1)

As a leding China manufacturer, Wzonpa delivers the 11KV Indoor vacuum Load Break Switch engineered for medium-voltage distribution systems. Designed with a compact integrated structure, this switch combines load breaking, grounding, and protection functions into a single unit, ensuring safe and efficient power control in indoor switchgear assemblies.


What is 11KV Indoor Vacuum Load Break Switch?

The 11KV Indoor vacuum Load Break Switch is a key switching device used to control, protect, and isolate electrical circuits under normal load conditions.


Core Functions

Load switching: Safely connects and disconnects rated current

Isolation: Provides visible and reliable disconnection

Arc extinction: Uses vacuum interrupter to ensure clean interruption

Safety grounding: Works with interlocking systems to prevent misoperation


Key Advantages

1.Compact Integrated Structure

Combines load switch, grounding switch, and mechanism in one frame

Reduces installation space and simplifies panel design


2.Advanced Vacuum Arc Technology

Fast dielectric recovery ensures stable arc interruption

Minimizes wear and extends service life


3.Reliable Mechanical Interlocking

Prevents incorrect operation between grounding and load switch

Fully compliant with “five-prevention” safety requirements


4.Flexible Operation Modes

Supports manual and electric operation

Compatible with AC/DC auxiliary control systems


Working Principle

1.Vacuum Interruption Mechanism

Contacts separate inside sealed vacuum chamber

Arc is quickly extinguished due to high dielectric strength


2.Energy Storage Operation

Spring mechanism ensures rapid opening/closing

Independent of operator speed for consistent performance


3.Safety Interlock Logic

Grounding switch cannot close unless load switch is open

Guarantees safe maintenance conditions


Application Scenarios

The 11KV Indoor vacuum Load Break Switch is widely used in:

Power Distribution Systems

Ring main units (RMU)

Medium-voltage switchgear panels


Industrial Facilities

Factories and processing plants

Mining and petrochemical systems


Infrastructure Projects

Commercial buildings

Substations and urban grid networks


Why Choose Wzonpa

More compact than traditional air or oil switches

Maintenance-free vacuum interrupter design

Higher safety with integrated interlocking system

Better adaptability for modern smart grid systems

The 11KV Indoor vacuum Load Break Switch offers improved reliability and operational safety compared to conventional switching devices.


Appearance and installation dimensions


Technical parameters

SN Item Unit Parameters
FZN25-12D/T630-20 FZRN25-12D/T125-31.5
1           Rated voltage KV 12 
2  Rated frequency Hz 50 
3  Rated current A 630  125 
4  Rated
Insulation level
1-minute power frequency withstand voltage KV Arc extinguishing chamber fracture 30; To the ground, alternating 42;Isolation fracture 48
Lightning impulse withstand voltage KV Ground to ground, alternating 75; |solation fracture 85
5  Rated dynamic stability current(peak value) KA 50 
6  4S thermal stability current KA 20 
7  Rated Active load breaking current A 630  125 
8  Rated closed-loop breaking current A 630  125 
9  Rated cable charging breaking current A 10  10 
10  Disconnect the capacity of the no-load transformer KVA 1250  1250 
11  Rated short-circuit breaking current KA 31.5 
12  Rated transfer current, rated handover current A 2000 
13  Fuse model SDLAJ-12 SFLAJ-12
14  Impactor output energy J 2-5(medium)
15  Rated short-circuit closing current KA 50 
16  Rated dynamic stability current of grounding switch KA 50 
17  Grounding switch 2S thermal stability current KA 20 
18  Rated voltage of auxiliary circuit V AC/CD 220;110
19  Mechanical lifespan Times 10000 


FAQ

Q1: What applications is this switch mainly used for?

A: It is commonly installed in indoor medium-voltage switchgear such as ring main units and distribution panels to manage load switching and circuit isolation.


Q2: Can it operate under frequent switching conditions?

A: Yes, the vacuum interrupter and spring mechanism are designed to handle repeated operations with stable performance and minimal wear.


Q3: What makes the vacuum interrupter more reliable?

A: Vacuum provides rapid dielectric recovery, ensuring arcs are extinguished quickly without residue, reducing wear and maintenance needs.


Q4: How is operational safety ensured during use?

A: The built-in mechanical interlocking system prevents incorrect operations, ensuring safe switching sequences and grounding procedures.


Q5: What environments can it be installed in?

A: I t is suitable for indoor installations with controlled temperature, humidity, and non-corrosive conditions as specified.


Product show

Send Inquiry
Contact Info
  • Address

    No. 58 Binhainan Fourth Road, Economic Development Zone, Yueqing City, Wenzhou City, Zhejiang Province, China

For inquiries about switchgear, MV soft starter, surge protective device or price list, please leave your email to us and we will be in touch within 24 hours.
Rating:
5.0
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy