The 11KV Indoor Sf6 Load Break Switch from Wzonpa, a professional manufacturer and supplier in China is a medium-voltage switchgear device designed for 12kV distribution networks. It uses SF6 gas as the insulating and arc-extinguishing medium in a sealed environment, integrating load breaking, isolation, and earthing functions within a compact and maintenance-free structure suitable for modern power systems.
The 11KV Indoor Sf6 Load Break Switch manufactured by Wzonpa factory is engineered for indoor electrical distribution systems where space efficiency and operational stability are required. It is widely applied in ring main units, compact substations, and cable distribution panels.
SF6 gas sealed insulation system for stable dielectric strength
Three-position operation: closed, open, and grounded
Compact design suitable for confined installation spaces
Supports integration with fuse protection units (BRFLN36-12D type)
The 11KV Indoor Sf6 Load Break Switch ensures controlled switching of load current, cable charging current, and transformer no-load current in medium-voltage networks.
APG epoxy resin insulation structure improves dust and environmental resistance
Mechanical interlock system enhances operational safety
Pressure relief design for internal fault protection
Maintenance-free operation under rated conditions
The 11KV Indoor Sf6 Load Break Switch combines isolation and grounding into one system, reducing operational complexity in distribution control.
Application Scenarios
The 11KV Indoor Sf6 Load Break Switch is widely used in:
Ring main units (RMU)
Urban power grid renovation projects
Industrial distribution systems
Commercial buildings and infrastructure substations
Transformer and cable protection systems
Its adaptability makes the 11KV Indoor Sf6 Load Break Switch suitable for both new installations and system upgrades.
Quality & Compliance Assurance
Manufactured under strict quality control systems, each 11KV Indoor Sf6 Load Break Switch complies with IEC 60265-1 standards.
Full factory testing for dielectric and mechanical performance
Pressure and sealing verification before shipment
Stable operation under -35°C to +40°C environments
Designed for altitudes up to 2500m
Competitive Comparison
Compared with conventional air-insulated switches, the 11KV Indoor Sf6 Load Break Switch for sale offers:
Higher insulation reliability in compact space
Stronger arc extinguishing capability
Reduced maintenance requirements
Longer service life in harsh environments
Service & Support
Wzonpa provides technical guidance, customization options, and after-sales support to ensure stable integration of the 11KV Indoor Sf6 Load Break Switch into different power distribution systems.
Appearance and installation dimensions
Technical parameters
Ratings
Unit
Value
Rated voltage
kV
12
24
40.5
Rated lighting impulse withstand voltage
kV
75
125
170
Common value
Across the isolating distance
kV
85
145
195
Rated short duration power frequency withstand voltage
kV
28
50
70
Common value
Across the isolating distance
kV
32
60
80
Rated frequency
Hz
50/60
50/60
50/60
Rated current Ir
A
630
630
630
Rated short time withstand current
kA
25
20
20
Rated duration of short circuit
S
2
3
3
Rated peak withstand current
kA
62.5
50
50
Pole Distance
mm
200,210
210,250,275
350
Making and breaking tests(IEC 60265-1)for FLN36 switch
Mainly active load current
A
630
630
630
Chosed-loop distribution circuit current
A
630
630
630
Cable charging current
A
50 and 10
50 and 10
50 and 10
Line charging current
A
20
20
20
Cable and line charging current under earth faults
A
87
87
87
Short circuit making current
kA
62.5
50
50
Making and breaking tests(IEC 60420)for FRLN36 switch-fuse combination
Withstand and switch on the cut-off current of the fuse
kA
25
20
20
Breaking test with Ing preacing time of fuse
OK
OK
OK
Breaking capacity at rated transfer current
A
1530
920
630
Mechanical performance
Mechanical endurance of switch close/open
Ns
1000
Mechanical endurance of switch open/earth
Ns
1000
Ambient temperature
Maximum value
℃
55
Maximum value of 24h mean
℃
55
Minimum value
℃
-15
Altitude above sea level
m
≤1800
FAQ
Q1: What is the function of the 11KV Indoor Sf6 Load Break Switch?
A1: It is used to switch, isolate, and ground medium-voltage circuits safely in distribution systems up to 12kV.
Q2: Can the 11KV Indoor Sf6 Load Break Switch work with fuses?
A2: Yes, it can be combined with fuse units to provide short-circuit and overload protection for transformers and cables.
Q3: What insulation medium is used?
A3: SF6 gas is used as both insulating and arc-extinguishing medium in a sealed chamber.
Q4: Where is it commonly installed?
A4: It is commonly installed in RMUs, substations, cable branch boxes, and compact switchgear panels.
For inquiries about switchgear, MV soft starter, surge protective device or price list, please leave your email to us and we will be in touch within 24 hours.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy