Hot sale 40.5KV Outdoor Vacuum Circuit Breakers VCB Breaker is offered by leading China manufacturer Wzonpa. It is engineered to automatically open or close circuits under normal or fault conditions, protecting transformers, lines, and substations while maintaining system stability and operational safety.
The 40.5KV Outdoor Vacuum Circuit Breakers VCB Breaker is a high-voltage switching and protection device designed for 40.5kV three-phase 50Hz power networks. Wzonpa, a leading China manufacturer, supplier and factory, delivers this solution for stable interruption of load current, overload current, and short-circuit current in demanding outdoor environments, ensuring reliable grid protection under severe operating conditions.
Key Advantages
The 40.5KV Outdoor Vacuum Circuit Breakers VCB Breaker adopts advanced vacuum arc extinguishing technology and precision mechanical design to ensure long-term performance.
High breaking capacity with no external arc exposure, improving operational safety
Mechanical lifespan up to 10,000 operations for frequent switching environments
Strong insulation using epoxy resin casting and extended creepage distance
Optional spring or electromagnetic operating mechanism for flexible control needs
Built-in 0.2-level current transformer for accurate protection and metering signals
Intelligent anti-condensation system for stable outdoor performance
Working Conditions
Temperature range: -25℃ to +40℃
Wind resistance: up to 34m/s
Altitude: ≤3000m without derating
Seismic resistance: up to intensity 8
Pollution level: Class III suitable
No explosive or strong corrosive environments required
Applications
The 40.5KV Outdoor Vacuum Circuit Breakers VCB Breaker made in China is widely used in substations, industrial and mining power distribution systems, rural grids, and renewable energy integration stations where stable switching performance is critical under frequent operations and harsh outdoor exposure.
Quality & Manufacturing Assurance
Wzonpa applies strict quality control throughout production, from raw material selection to final testing. High-voltage withstand tests, mechanical endurance checks, and insulation verification are conducted to ensure compliance with international power equipment standards and long-term operational reliability.
Why Choose Us
Compared with conventional circuit breakers, Wzonpa solutions offer improved durability, reduced maintenance frequency, and enhanced environmental adaptability. The 40.5KV Outdoor Vacuum Circuit Breakers VCB Breaker provides superior arc control performance and higher operational stability in extreme conditions.
Appearance and installation dimensions
Technical parameters
SN
Item
Unit
Parameters
1
Rated voltage
KV
40.5
2
Rated insulated level
Power frequency withstand voltage
Dry-type
95
Wet-type
80
Lightning impulse withstand
voltage(peak value)
185
3
Rated
current
A
1250、
1600、2000
4
Rated
short-circuit breaking current
KA
20、25、31.5
5
Rated
operating sequence
O-0.3s-CO-180s-CO
6
Rated
short-circuit current breaking times
Times
12
7
Rated
short-circuit closing current (peak)
KA
50、63、80
8
Rated
peak withstand current
6
Rated
short-time withstand current
KA
20、25、31.5
10
Rated
short-circuit continuous current
S
4
11
Average
opening speed
m/s
1.5±0.2
12
Average
closing speed
0.7±0.2
13
Contact
closing bounce time
S
≤2
14
Three
phase closing(opening)synchronization time difference
≤2
15
Closing
time
≤150
16
Opening
time
≤60
17
Mechanical
lifespan
Times
10000
18
Rated
operating voltage and rated voltage of auxiliary circuit
V
DC220、110、24
AC220、110、24
19
DC
resistance of each phase circuit(excluding transformers)
μΩ
≤100
20
Allowable
wear thickness of dynamic and static contacts
mm
3
21
weight
kg
800
FAQ
Q1: What is the main function of this circuit breaker?
A1: It protects electrical systems by interrupting fault currents and ensuring safe operation of power distribution networks under overload or short-circuit conditions.
Q2: Can it be used in high-altitude areas?
A2: Yes, it is designed for stable operation up to 3000 meters without performance reduction.
Q3: What makes vacuum technology better?
A3: Vacuum interruption eliminates external arc risk, improving safety and extending service life.
Q4: How often does it require maintenance?
A4: With optimized design and long-life mechanism, maintenance intervals are significantly reduced compared to traditional equipment.
For inquiries about switchgear, MV soft starter, surge protective device or price list, please leave your email to us and we will be in touch within 24 hours.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy